The AMIL method

doc48 These gates can be modelled directly in Hydraulic mode from SIC Version 4.0. It is better to use this new option. Nevertheless the previous option using a regulation module is still available.

For the AMIL gates, the variables D, d, HA and FILTRE must be given under the format (3(F8.2,1X),F8.2):

Remark: The radius of the gate R is calculated from D and the constructor table (63, 63, 63, 63, 90, 90, 90, 125, 125, 125, 160, 160, 200, 200, 250, 250, 315, 315, 400, 400, 450),

Remark: D and R are given in the above tables in centimeters. In the software, these variables are converted into (m), when reading the .REG file. These converted variables (in meters) are the ones written on the .LST file. If the decrement d is not provided (i.e. equal to zero), we take d = 2% of D (d=0.05*D).

An example of regulation file (.REG) for the AMIL gate is given bellow. The calculation routine CAMIL for the AMIL gate is given in the following section.