Importing an initial condition for a transient flow simulation

This command simply allows importing the result of a steady or transient simulation of a scenario or variant into the initial conditions of a scenario or variant, so that a transient flow simulation (SIRENE) can be launched.

Command line syntax:

EDISIC.EXE "Working_directory" CI "File.XML" [ResSce] [ResVar] [ResTps] [CiSce] [CiVar]

Description of the command line parameters

  • "Working_directory" : directory where the model XML file is located
  • CI : command to EdiSic to launch the import of initial conditions
  • "File.XML" : File where the model to be processed is located. -[ResSce] : number of the scenario containing the simulation result to import
  • [ResVar] : number of the variant containing the simulation result to import
  • [ResTps] : time (in seconds) of the simulation result to import
  • [CiSce] : Scenario to which the initial condition is imported
  • [CiVar] : Variant to which the initial condition is imported

Usage example on the file C:/titi/toto.xml

To import the result at time 0 of scenario 1 into variant 1 of scenario 1: EDISIC.EXE "C:/titi" CI "toto.xml" 1 0 0 1 1

To import the result at 6 hours of variant 1 of scenario 1 into variant 2 of the same scenario: EDISIC.EXE "C:/titi" CI "toto.xml" 1 1 21600 1 2